The FLATLITE®
system

Jump to:
Lamp
AC Power Supply (Inverter)
DC Power Supply (Inverter)
Control (dimming/flashing)
Connections & terminations
Fixtur
Lamp
Basic
Colors:
| Green/Blue -
utilizes
a mix of natural Blue & Green phosphor crystals which, combined, give the best
brightness and life available. Appears off white when not powered.

|
White
Made by adding a dye to the phosphor mix during manufacturing. When
energized, the Blue/Green color is shifted by the dye to appear as a pure White color of
5400 degrees Kelvin. Appears pink in color when not powered.

|
Color
Overlays
For lamp
widths of 6 inches (152.4 mm) or less, other colors are created by adhering and laminating
colored gel material to the standard Green/Blue and White FLATLITE® lamp. The six
color overlays are: Yellow, Red, Magenta, Green, Blue, & Orange.

Lamination
Indoor
Grade: laminated with a standard polyester material that resists humidity up to 70%.
Outdoor
grade: a specially formulated laminate that provides up to 99% humidity protection
plus ultraviolet (UV) protection to stand up to sun exposure.
FLATLITE SKU:
 |
| LAMINATE: |
UNIT: |
COLOR: |
| "D" = Indoor (dry) |
"FL" =
By the foot |
"G" = Green/blue (no overlay) |
| "W" = Outdoor (wet) |
"C1" =
100' (30.48m) coil (strips only) |
"W" = White (no overlay) |
| "U" = Unlaminated |
"C3" =
300' (91.44m) coil (strips only) |
"O" = Orange Overlay |
|
"C5" =
50' (15.24m) coil (panels only) |
"B" = Blue Overlay |
WIDTHS: |
|
"N" = Green Overlay |
| See charts below |
|
"R" = Red Overlay |
|
|
"Y" = Yellow Overlay |
|
|
"M" = Magenta Overlay |
|
|
|
| 'FLATLITE WIDTHS' refer to the lighted
width of the lamp. The overall lamp dimensions include the protective laminate as
indicated here: |
|
|
 |
"Panel"
Widths
| Inches |
Millimeters |
SKU |
| 9 |
228.6 |
0900 |
| 12 |
304.8 |
1200 |
| 15 |
381 |
1500 |
| 18 |
457.2 |
1800 |
| 21 |
533.4 |
2100 |
| 24 |
609.6 |
2400 |
| 30 |
762 |
3000 |
|
"Strip"
Widths:
| Inches |
Millimeters |
SKU |
| 0.25 |
6.35 |
0025 |
| 0.50 |
12.7 |
0050 |
| 1.0 |
25.4 |
0100 |
| 2.0 |
50.8 |
0200 |
| 3.0 |
7602 |
0300 |
| 6.0 |
152.4 |
0600 |
|
Standard Coil Lengths:
| Width |
Length |
| 6" / 15.24 cm or less (Strip widths) |
100' (30.48m) or 300' (91.44) |
| Greater then 6" /15.24 cm (Panel widths) |
50' (15.24 m) |
|
|
|
Power Supplies: AC Mains Input
Select power supply based on the total square inches that it will light.
Input Power: 110/240VAC, 50/60 Hz
(Note: These
inverters should never be connected to a dimmable circuit. Use CMD modules)
Specs:
| MODEL |
DIMENSIONS
Width
x Length x Height |
WEIGHT |
MAX POWER |
LAMP AREA |
| 600N |
3.6"
x 8.3" x 3.1"
9.2cm
x 21cm x 7.9cm |
2lb 8oz
1.1 kg |
30 watts |
100-600
in2
645-3900
cm2 |
| 2200N-A |
3.75"
x 10.5" x 3.25"
9.5cm
x 26.7cm x 8.3cm
|
3lb 12oz
1.7 kg |
90 watts |
600-1800
in2
3900-11600
cm2 |
| 2200N-B |
100 watts |
1800-2600
in2
11600-16800
cm2 |
| 12KN-A |
9"
x 13.4" x 4"
23.4cm
x 34cm x 10.2cm
|
7lb 5oz
3.3 kg |
155 watts |
2600-3500
in2
16800-22600
cm2 |
| 12KN-B |
9lb 13oz
4.4 kg |
240 watts |
3100-5300
in2
20000-34200
cm2 |
| 12KN-C |
12lb 5oz
5.6 kg |
390 watts |
4800-8000
in2
30900-51600
cm2 |
| 12KN-D |
14lb 13oz
6.7 kg |
625 watts |
7800-12500
in2
50300-80600
cm2 |
Power Supplies: DC Input
Pick power supply based on the total square inches that it will light.
12V and 24V DC (Vcc) Input Compensating Inverters
|
LAMP
RANGE
(inverter
powers lamp within this area range) |
WIDTH |
HEIGHT |
LENGTH |
| Inverter Model |
inches2 |
cm2 |
inches |
cm |
inches |
cm |
inches |
cm |
Max Current Required |
| PS60N |
5-60 |
30-390 |
2 |
5.8 |
1.5 |
3.8 |
2 |
5.8 |
250mA |
| PS125N |
15-125 |
100-800 |
2 |
5.8 |
1.5 |
3.8 |
3 |
7.6 |
500mA |
| PS60N-CM |
5-60 |
30-390 |
2 |
5.8 |
1.5 |
3.8 |
3 |
7.6 |
250mA |
| PS125N-CM |
15-125 |
100-800 |
2 |
5.8 |
1.5 |
3.8 |
3 |
7.6 |
500mA |
| DC41EL-129-150 |
129-150 |
830-968 |
4 |
10.16 |
2 |
5.08 |
2.19 |
5.56 |
560mA |
| DC50EL-151-250 |
150-250 |
968-1613 |
5.75 |
14.61 |
2 |
5.08 |
2.19 |
5.56 |
940mA |
Control Modules
CMD-001 Analog Interface Module
Remote control interface enables
on-board dimming of lamp via interface with E-Lite Power Supplies.
CMD-002 Manual Dimming Module
A rotary dimmer switch is used
to manually dim the lamp.
CMD-004 Variable Flashing Module
Two flush-set screwdriver pots
(dials) are used to manually adjust the "On" time and the "Off" time
of the flashing lamp.
Connections & Terminations

Any of a number of different methods can be used to very simply attach
connectors to the lamp. E-Lite makes available ETCO and AMP brand connectors, but many
other types are commonly used.
See Connectors and Lamp
Termination - ETCO and AMP
for more information.
Fixtures

FLATLITE® is inherently safe with just the standard
indoor or outdoor laminate, but if it was punctured or cut, it would be electrically live.
In a decorative architecture application, FLATLITE® requires a fixture (extrusion)
for proper installation. There are as many ways to create a protective fixture for FLATLITE®
as there are uses for the product itself. E-Lite makes the following extrusions available:
| Extrusion SKU |
Lamp Strip Width (illuminated width, not overall lamp with) |
Extrusion Consists of: |
| EDT-0025C-5* |
1/4"
(0.635 cm) |
5' (1.52 m) long base
5'
(1.52 m) snap over lens |
| EDT-0075C-5* |
1/2"
(1.27 cm) |
5' (1.52 m) long base
5'
(1.52 m) snap over lens |
| ADT-0050C-10 |
1/2"
(1.27 cm) |
8' (2.44 m) long base
8'
(2.44 m) slide over lens |
| ADT-0100C-10 |
1"
(2.54 cm) |
8' (2.44 m) long base
8'
(2.44 m) slide over lens |
| ADL-0100C-8-SN |
1"
(2.54 cm) |
8' (2.44 m) long base
8'
(2.44 m) snap over lens |
| ADT-0300C-10 |
3"
(7.62 cm) |
8' (2.44 m) long base
8'
(2.44 m) slide over lens |
| ADT-0600C-10 |
6"
(15.24 cm) |
8' (2.44 m) long base
8'
(2.44 m) slide over lens |
| * used for egress applications. Based on Wiremold® 400
and 800 series raceway. Limited stock of 0075C available |
Download Acrobat Reader to read PDF files

top |